SKU
NEST.3Dbulkpack

NEST Cryovials 2D barcode on bottom, and 1D barcode on side, compatible with Brooks system, External threaded - Bulk packaging

Price $0.10

CUSTOMIZE YOUR PRODUCT

Wishlist

Ideal for cryopreservation of cells and other samples. The lowest temperature can withstand -196°C (with screw cap). All our polypropylene pipes are suitable for low temperature storage, except for liquid nitrogen.

 

Features:

  • Three-code-in-one (digital code, barcode, QR code):
  • The product meets the SBS standard and provides an effective safety guarantee and management for biological sample libraries and other warehouses of various chemicals and biological products stored at low temperatures, making the warehousing and exwarehousing of samples more convenient and faster.
  • The vial has laser-etched international standard DATAMATRIX 2D code at the bottom.
  • The barcode and digital code at the side are anti-fading, anti-deforming, wear proof and resist DMSO and other organic solvents, 100% clear and readable
  • It can support the traceability of samples and data sharing among multiple users, laboratories and automation

 

Material Characteristics:

  • The vial body is made of medical-grade cryogenic polypropylene (PP), which meets USP Class-6 standards and the vial cap is made of high density polyethylene (HDPE). it is recommended that the vial be used in the gas phase above -196 ℃ liquid nitrogen
  • Withstand temperature range: Approx.-196°C to 121°C.
  • DNase/RNase free, non-endotoxin.
  • Electron beam sterilization, SAL = 10 -6.
  • Two-color tube body integral injection molding

 

NEST Advantages: Testing and control in strict accordance with quality requirements

1. Low temperature test: -80℃ cryogenic freezing test, -196℃ liquid nitrogen test.
2. Sealing test
3. Sterility test
4. Endotoxin test, DNA and RNA enzyme test.

 

Precautions:

  1. After the cryogenic vial is taken out of the liquid nitrogen, its bottom should be wiped with a dry towel, so that the QR code can be better identified;
  2. The freezing storage sample size should not exceed the maximum working volume required by the cryogenic vial;
  3. During the freezing storage, the vial cap must be tightened, to prevent liquid nitrogen from entering during the freezing process;
  4. Before the cryogenic vial is taken out of the liquid nitrogen, proper protective measures should be taken first, to avoid causing safety problems in the laboratory.

 

Warning:

  1. Do not use cryogenic vials for storage in the liquid phase of liquid nitrogen. Only store vials in the vapor phase above the liquefied gas.
  2. Always use appropriate safety equipment when removing vials from cryogenic storage.

 

 

 

Specifications

Product Range

Description /Pk /Cs
3D Barcode 1.9mL Cryogenic Vial, SBS Format, Compatible with Brooks System, Self-Standing, External Thread, Caps on, Sterile 48 480
3D Barcode 1.9mL Cryogenic Vial, SBS Format, Compatible with Brooks System, Self-Standing, External Thread, Caps Separated, Sterile 48 480
3D Barcode 4.0mL Cryogenic Vial, SBS Format, Compatible with Brooks System, Self-Standing, External Thread, Caps on, Sterile 48 480
3D Barcode 4.0 mL Cryogenic Vial, SBS Format, Compatible with Brooks System, Self-Standing, External Thread, Caps Separated,
Sterile
48 480
Overview

Ideal for cryopreservation of cells and other samples. The lowest temperature can withstand -196°C (with screw cap). All our polypropylene pipes are suitable for low temperature storage, except for liquid nitrogen.

 

Features:

  • Three-code-in-one (digital code, barcode, QR code):
  • The product meets the SBS standard and provides an effective safety guarantee and management for biological sample libraries and other warehouses of various chemicals and biological products stored at low temperatures, making the warehousing and exwarehousing of samples more convenient and faster.
  • The vial has laser-etched international standard DATAMATRIX 2D code at the bottom.
  • The barcode and digital code at the side are anti-fading, anti-deforming, wear proof and resist DMSO and other organic solvents, 100% clear and readable
  • It can support the traceability of samples and data sharing among multiple users, laboratories and automation

 

Material Characteristics:

  • The vial body is made of medical-grade cryogenic polypropylene (PP), which meets USP Class-6 standards and the vial cap is made of high density polyethylene (HDPE). it is recommended that the vial be used in the gas phase above -196 ℃ liquid nitrogen
  • Withstand temperature range: Approx.-196°C to 121°C.
  • DNase/RNase free, non-endotoxin.
  • Electron beam sterilization, SAL = 10 -6.
  • Two-color tube body integral injection molding

 

NEST Advantages: Testing and control in strict accordance with quality requirements

1. Low temperature test: -80℃ cryogenic freezing test, -196℃ liquid nitrogen test.
2. Sealing test
3. Sterility test
4. Endotoxin test, DNA and RNA enzyme test.

 

Precautions:

  1. After the cryogenic vial is taken out of the liquid nitrogen, its bottom should be wiped with a dry towel, so that the QR code can be better identified;
  2. The freezing storage sample size should not exceed the maximum working volume required by the cryogenic vial;
  3. During the freezing storage, the vial cap must be tightened, to prevent liquid nitrogen from entering during the freezing process;
  4. Before the cryogenic vial is taken out of the liquid nitrogen, proper protective measures should be taken first, to avoid causing safety problems in the laboratory.

 

Warning:

  1. Do not use cryogenic vials for storage in the liquid phase of liquid nitrogen. Only store vials in the vapor phase above the liquefied gas.
  2. Always use appropriate safety equipment when removing vials from cryogenic storage.

 

 

 

Copyright © 2008-2023 Across International. All rights reserved.