The store will not work correctly in the case when cookies are disabled.
We use cookies to make your experience better.To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
The all new Ai Glacier 21 Cu Ft -86C ultra low Temprature chest freezer is perfect for extra-large storage of sample and products. Our unique dual parallel compressor design offers you speedy cooling and great temperature uniformity inside the chamber.
Features
CDC and VFC compliant, great for storage of vaccines, DNA, RNA, virus samples, organs, and serum
Remote alarm, R485, 4-20mA transmitter (optional)
ETL tested to UL and CSA standards
ETL tested to UL 471, Commercial Refrigerators and Freezers standards (optional)
All stainless steel interior for clean operation, durability, and ease of maintenance
External door with hydraulic support for super ease of operationPowerful dual parallel compressor design for speedy cooling and great temperature uniformity
Central control with large 7" touch screen LCD display provides you a graph of temperature vs time curve.
Lock-able door, high or low temperature alarms, power failure alarm, door open alarm, filter clogging alarm, password protection, tons of security features to protect you, your products, and the unit
Dual silicon sealing gaskets for ultra airtight operation
24-hour battery backup for controller
USB interface for data export and storage
Extremely quiet and reliable
Environmental friendly refrigerant
Use only RoSH compliant non-toxic components and materials
Tons of safety functions
Data storage Q & A
Q: How long can we store temperature data files continuously? A: A total of 100,000 sets of data can be stored.
Q: What is the temperature data sampling rate? A: Default sampling rate is 10 minutes (52,560 data sets per year), 100,000 data sets can be stored for less than two years.
Q: Will the freezer delete stored data itself? A: Yes, after reaching 100,000 data sets, the oldest data set will be automatically deleted for each new data set recorded.
Q: Does freezer offer users option to automatically delete .dtl files that do not need to be stored? A: No. It is recommended to copy the data on the freezer regularly to a computer for backup. In addition, data will be lost after replacing a display board, so do backup the data before replacing a display board.
Important!
Do not plug in your unit. Leave your Ai refrigerator or freezer for 24 hours before turning the unit on for the first time.
This unit is NOT designed to be used on a mobile platform.
Temperature range: -40°C to -86°C Time to reach -86°C: 6 hours
Compressor
Make: SECOP Model: SC18MLX (104L2138) Power: 220V 60Hz 1-PHASE 1HP Number of compressors: two, parallel Refrigerant: Ai proprietary mixture gases, CFC-free
Chamber
Dimensions: 47 x 32 x 24" (WxDxH) Material: 304 stainless steel Volume: 21 Cu Ft Maximum load capacity: 550 Lbs on the base of chamber, evenly distributed
Cover and gasket
External door: dual-level sealing gasket, lock-able, with hydraulic support Interior covers: three pieces removable foam
Access port
Two, one on the side and one in the back, one inch diameter
- Temperature: 10°C to 32°C (humidity <57% Rh required at 32°C) - Humidity: <80% Rh - Altitude: < 2000 m / 6561 Ft - Stable, well-ventilated platform with no excessive dust - Keep freezer at least 12 inches from any walls or ceiling - Use dedicated power, do not share outlet - Extension power cable should be less than 10 feet is required - Freezer and power outlet should be grounded properly - Avoid direct sunlight, water spill and do NOT use freezer outdoor - Clean condenser fins and remove frost inside chamber at least once a month - Important! Do not plug in your unit. Leave your Ai refrigerator or freezer for 24 hours before turning the unit on for the first time.
Battery backup system
24 hours (for controller display and alarms only)
Unit/shipping weight & dimensions
900 Lbs / 1100 Lbs 80 x 47 x 41" / 84 x 51 x 48" (WxDxH)
Safety
Compressor over-temp protection Compressor power surge delay protection Short circuit and ground protection Over-current protection Over-temperature and low-temperature protection Power failure protection Low battery, door open, filter clogging, system failure alarms External door with lock
Compliance
UL STD 61010-1 (standard) UL STD 471 (optional) CSA C22.2 NO. 61010-1 (standard)
The all new Ai Glacier 21 Cu Ft -86C ultra low Temprature chest freezer is perfect for extra-large storage of sample and products. Our unique dual parallel compressor design offers you speedy cooling and great temperature uniformity inside the chamber.
Features
CDC and VFC compliant, great for storage of vaccines, DNA, RNA, virus samples, organs, and serum
Remote alarm, R485, 4-20mA transmitter (optional)
ETL tested to UL and CSA standards
ETL tested to UL 471, Commercial Refrigerators and Freezers standards (optional)
All stainless steel interior for clean operation, durability, and ease of maintenance
External door with hydraulic support for super ease of operationPowerful dual parallel compressor design for speedy cooling and great temperature uniformity
Central control with large 7" touch screen LCD display provides you a graph of temperature vs time curve.
Lock-able door, high or low temperature alarms, power failure alarm, door open alarm, filter clogging alarm, password protection, tons of security features to protect you, your products, and the unit
Dual silicon sealing gaskets for ultra airtight operation
24-hour battery backup for controller
USB interface for data export and storage
Extremely quiet and reliable
Environmental friendly refrigerant
Use only RoSH compliant non-toxic components and materials
Tons of safety functions
Data storage Q & A
Q: How long can we store temperature data files continuously? A: A total of 100,000 sets of data can be stored.
Q: What is the temperature data sampling rate? A: Default sampling rate is 10 minutes (52,560 data sets per year), 100,000 data sets can be stored for less than two years.
Q: Will the freezer delete stored data itself? A: Yes, after reaching 100,000 data sets, the oldest data set will be automatically deleted for each new data set recorded.
Q: Does freezer offer users option to automatically delete .dtl files that do not need to be stored? A: No. It is recommended to copy the data on the freezer regularly to a computer for backup. In addition, data will be lost after replacing a display board, so do backup the data before replacing a display board.
Important!
Do not plug in your unit. Leave your Ai refrigerator or freezer for 24 hours before turning the unit on for the first time.
This unit is NOT designed to be used on a mobile platform.