Digital temperature controlled recirculating water chiller with built-in swivel casters, recommended for our IH series induction heaters (see models below). These chillers have built-in stainless steel tank, water pump and tubing for durability and rust-free operations. Water manifold included for immediate use.
Manual Pressure Control Valve for 0 to 80 psi is an optional add-on, not standard with every unit
Digital micro-chip controlled with LCD screen and fluid level display
Input power
480VAC 60Hz three-phase (3PH) 3.75kW
Nominal cooling capacity
10366 kcal per hour 10°C, cooling capacity 8175W 15°C, cooling capacity 10198W Nominal cooling capacity is according to: Inlet chilled fluid temperature: 12°C Outlet chilled fluid temperature: 7°C Inlet cooling air temperature: 30°C Outlet cooling air temperature: 35°C
Compressor
Make: Danfoss (UL Listed) Power: 460V 3-60Hz 8A 3750 watts, LR 25A, thermally protected Refrigerant: R407C (2,400g) PS: 22.6 bar, TS max: 50°C, TS min: -35°C Number of compressors installed: one
Water pump
Make: LX (CMF2-50T-A-W-G-BABE) Power: 480V 60Hz 3-PH 550 watts 2.5/Y1.4A 3450 rpm IP55 Max liquid temperature: 70°C Pumping speed: 33L per minute Max pressure: 10 bar. H(max): 64m, H(n): 51m
Reservoir capacity
35L
Recommended coolant
Distilled water
Cooling fan
Make: Weiguang (YWF4D-350S-102/34-G) Power: 480V 60Hz 80/150 watts 0.27A 1640 rpm Number of fans installed: two Flow rate: 142,000 cu ft per hour
Temperature accuracy
+/- 2 °C
Water inlet & outlet on chiller
1.5" inch Tri-Clamp
Water manifold
Inlet: 1.5” inch Tri-clamp, manifold: one 1” inch, two 8mm quick connect with ball valve
Unit/shipping weight
375 Lb / 485 Lb
Unit/shipping dimensions
41 x 22 x 54" / 50 x 25 x 61" (DxWxH)
Safety
Over current, compressor delay start, water pump over load, built-in fuse, over-voltage and under- voltage, abnormal operations, phase protection and
Working environment
Temperature range of chilled fluid: 5°C - 35°C. Temperature difference of chilled fluid between inlet and outlet: 3°C - 8°C. It is better to use the chiller while the ambient temperature is at or below 35°C
Recommended to use with these induction heaters (result may vary on different applications)
High frequency 10kW, 20kW, 30kW Mid frequency 25kW, 35kW, 70kW Low frequency 25kW, 35kW
Digital temperature controlled recirculating water chiller with built-in swivel casters, recommended for our IH series induction heaters (see models below). These chillers have built-in stainless steel tank, water pump and tubing for durability and rust-free operations. Water manifold included for immediate use.
Manual Pressure Control Valve for 0 to 80 psi is an optional add-on, not standard with every unit